ELECTRON MICROSCOPY
Starting Model(s)
Initial Refinement Model(s) | |||
---|---|---|---|
Type | Source | Accession Code | Details |
experimental model | PDB | 5MW2 |
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
f_dihedral_angle_d | 20.5229 |
f_angle_d | 1.0961 |
f_chiral_restr | 0.057 |
f_bond_d | 0.0123 |
f_plane_restr | 0.0056 |
Sample |
---|
B-cell lymphoma 6 protein (BCL6) filament |
Specimen Preparation | |
---|---|
Sample Aggregation State | FILAMENT |
Vitrification Instrument | LEICA EM GP |
Cryogen Name | ETHANE |
Sample Vitrification Details | 4 ul sample applied twice, blotted 1.3s each time |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 112048 |
Reported Resolution (Å) | 3.7 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | as implemented in Relion |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C1 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (5MW2) | ||||
Refinement Space | REAL | ||||
Refinement Protocol | RIGID BODY FIT | ||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details | Real_space_refine: global minimization, rigid body and adp refinement with target restraints. |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K3 BIOQUANTUM (6k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 63.4 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | -1000 |
Maximum Defocus (nm) | -2500 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 105000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details | Data collection in counting mode, using multi shot scheme (4 holes per stage position, 2 shots per hole) |
EM Software | ||
---|---|---|
Task | Software Package | Version |
PARTICLE SELECTION | crYOLO | |
IMAGE ACQUISITION | SerialEM | |
CTF CORRECTION | CTFFIND | |
CTF CORRECTION | RELION | |
MODEL FITTING | Coot | 0.89 |
MODEL REFINEMENT | PHENIX | 1.17 |
INITIAL EULER ASSIGNMENT | RELION | 3.0 |
FINAL EULER ASSIGNMENT | RELION | 3.0 |
CLASSIFICATION | RELION | 3.0 |
RECONSTRUCTION | RELION | 3.0 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | Standard CTF correction in relion, based on parameters estimated by CTFFIND4 | 1610413 | particles picked with crYOLO |