SOLUTION NMR
| NMR Experiment | ||||||||
|---|---|---|---|---|---|---|---|---|
| Experiment | Type | Sample Contents | Solvent | Ionic Strength | pH | Pressure | Temperature (K) | Spectrometer |
| 1 | 2D 1H-1H TOCSY | 1.6mM kalata B7 | 90% H2O/10% D2O | 0 | 2.6 | ambient | 303 | |
| 2 | 2D DQF-COSY | 1.6mM kalata B7 | 90% H2O/10% D2O | 0 | 2.6 | ambient | 303 | |
| 3 | 2D 1H-1H NOESY | 1.6mM kalata B7 | 90% H2O/10% D2O | 0 | 2.6 | ambient | 303 | |
| 4 | 1D 1H | 1.6mM kalata B7 | 90% H2O/10% D2O | 2.6 | 313 | |||
| 5 | 2D 1H-1H NOESY | 0.6mM kalata B7 | 90% H2O/10% D2O | 5.0 | 313 | |||
| 6 | 1D invertion-recovery | 0.6mM kalata B7 | 90% H2O/10% D2O | 5.0 | 313 | |||
| NMR Spectrometer Information | |||
|---|---|---|---|
| Spectrometer | Manufacturer | Model | Field Strength |
| 1 | Varian | UNITY | 600 |
| 2 | Bruker | DRX | 500 |
| NMR Refinement | ||
|---|---|---|
| Method | Details | Software |
| simulated annealing | XEASY | |
| NMR Ensemble Information | |
|---|---|
| Conformer Selection Criteria | target function |
| Conformers Calculated Total Number | 100 |
| Conformers Submitted Total Number | 20 |
| Representative Model | 1 (fewest violations) |
| Computation: NMR Software | ||||
|---|---|---|---|---|
| # | Classification | Version | Software Name | Author |
| 1 | chemical shift assignment | XEASY | Bartels et al. | |
| 2 | peak picking | XEASY | Bartels et al. | |
| 3 | collection | VNMR | Varian | |
| 4 | processing | VNMR | Varian | |
| 5 | collection | XwinNMR | Bruker Biospin | |
| 6 | processing | XwinNMR | Bruker Biospin | |
| 7 | structure solution | CYANA | 1.1 | Guntert, Mumenthaler, Wuthrich |
| 8 | geometry optimization | CYANA | 1.1 | Guntert, Mumenthaler, Wuthrich |
| 9 | data analysis | CYANA | 1.1 | Guntert, Mumenthaler, Wuthrich |
| 10 | geometry optimization | MOLMOL | Koradi, Billeter, Wuthrich | |
| 11 | pictures preparation | MOLMOL | Koradi, Billeter, Wuthrich | |
| 12 | refinement | CYANA | 1.1 | Guntert, Mumenthaler, Wuthrich |