SOLUTION NMR
| NMR Experiment | ||||||||
|---|---|---|---|---|---|---|---|---|
| Experiment | Type | Sample Contents | Solvent | Ionic Strength | pH | Pressure | Temperature (K) | Spectrometer |
| 1 | 2D DQF-COSY | 3.0 mM Hge36 | 95% H2O/5% D2O | 3 mM | 3.0 | 585 mmHg | 25 | Varian INOVA 500 |
| 2 | 2D 1H-1H NOESY | 3.0 mM Hge36 | 95% H2O/5% D2O | 3 mM | 3.0 | 585 mmHg | 25 | Varian INOVA 500 |
| 3 | 2D 1H-1H TOCSY | 3.0 mM Hge36 | 95% H2O/5% D2O | 3 mM | 3.0 | 585 mmHg | 25 | Varian INOVA 500 |
| 4 | 2D 1H-15N HSQC | 3.0 mM [U-13C; U-15N] Hge36 | 95% H2O/5% D2O | 3 mM | 3.0 | 585 mmHg | 25 | Varian INOVA 500 |
| 5 | 2D 1H-13C HSQC | 3.0 mM [U-13C; U-15N] Hge36 | 95% H2O/5% D2O | 3 mM | 3.0 | 585 mmHg | 25 | Varian INOVA 500 |
| 10 | 3D CBCA(CO)NH | 3.0 mM [U-13C; U-15N] Hge36 | 95% H2O/5% D2O | 3 mM | 3.0 | 585 mmHg | 25 | Varian INOVA 500 |
| 9 | 3D HNCO | 3.0 mM [U-13C; U-15N] Hge36 | 95% H2O/5% D2O | 3 mM | 3.0 | 585 mmHg | 25 | Varian INOVA 500 |
| 8 | 3D HNCA | 3.0 mM [U-13C; U-15N] Hge36 | 95% H2O/5% D2O | 3 mM | 3.0 | 585 mmHg | 25 | Varian INOVA 500 |
| 7 | 3D HN(CO)CA | 3.0 mM [U-13C; U-15N] Hge36 | 95% H2O/5% D2O | 3 mM | 3.0 | 585 mmHg | 25 | Varian INOVA 500 |
| 6 | 3D HNCACB | 3.0 mM [U-13C; U-15N] Hge36 | 95% H2O/5% D2O | 3 mM | 3.0 | 585 mmHg | 25 | Varian INOVA 500 |
| 11 | 3D 1H-15N NOESY | 3.0 mM [U-13C; U-15N] Hge36 | 95% H2O/5% D2O | 3 mM | 3.0 | 585 mmHg | 25 | Varian INOVA 500 |
| 12 | 3D 1H-15N TOCSY | 3.0 mM [U-13C; U-15N] Hge36 | 95% H2O/5% D2O | 3 mM | 3.0 | 585 mmHg | 25 | Varian INOVA 500 |
| 13 | 2D 1H-1H TOCSY | 3.0 mM [U-13C; U-15N] Hge36 | 95% H2O/5% D2O | 3 mM | 3.0 | 585 mmHg | 25 | Bruker AVANCE III 700 |
| 15 | 2D 1H-1H NOESY | 3.0 mM Hge36 | 95% H2O/5% D2O | 3 mM | 3.0 | 585 mmHg | 25 | Bruker AVANCE III 700 |
| NMR Spectrometer Information | |||
|---|---|---|---|
| Spectrometer | Manufacturer | Model | Field Strength |
| 1 | Varian | INOVA | 500 |
| 2 | Bruker | AVANCE III | 700 |
| NMR Ensemble Information | |
|---|---|
| Conformer Selection Criteria | |
| Conformers Calculated Total Number | |
| Conformers Submitted Total Number | 20 |
| Computation: NMR Software | ||||
|---|---|---|---|---|
| # | Classification | Version | Software Name | Author |
| 1 | processing | NMRPipe | Delaglio, Grzesiek, Vuister, Zhu, Pfeifer and Bax | |
| 2 | data analysis | CARA | Keller and Wuthrich | |
| 3 | chemical shift assignment | CARA | Keller and Wuthrich | |
| 4 | peak picking | CARA | Keller and Wuthrich | |
| 5 | chemical shift assignment | CARA | Keller and Wuthrich | |
| 6 | chemical shift assignment | CYANA | Guntert, Mumenthaler and Wuthrich | |
| 7 | structure calculation | CYANA | Guntert, Mumenthaler and Wuthrich | |
| 8 | refinement | Amber | Case, Darden, Cheatham III, Simmerling, Wang, Duke, Luo, ... and Kollman | |














