8YY1

Vo domain of V/A-ATPase from Thermus thermophilus state3


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 6QUM 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d4.011
f_angle_d0.476
f_chiral_restr0.038
f_plane_restr0.005
f_bond_d0.002
Sample
Vo domain of V/A-ATPase from thermus thermophilus.
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification Instrument
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles26525
Reported Resolution (Å)3.6
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1 (6QUM)
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)50
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)800
Maximum Defocus (nm)2000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS0.105
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONTopaz
CTF CORRECTIONCTFFIND4.1.8
MODEL FITTINGPHENIX1.20
MODEL REFINEMENTISOLDE1.3
INITIAL EULER ASSIGNMENTRELION
FINAL EULER ASSIGNMENTRELION4.01
CLASSIFICATIONRELION4.01
RECONSTRUCTIONRELION4.01
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION