6XKK | pdb_00006xkk

Cryo-EM structure of the NLRP1-CARD filament


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 4IFP 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg31.606
r_dihedral_angle_4_deg18.183
r_dihedral_angle_3_deg14.527
r_dihedral_angle_1_deg4.304
r_angle_refined_deg1.206
r_chiral_restr0.091
r_bond_refined_d0.006
r_gen_planes_refined0.006
r_bond_other_d
r_angle_other_deg
Sample
NLRP1-CARD filament
Specimen Preparation
Sample Aggregation StateFILAMENT
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodHELICAL
Number of Particles18272
Reported Resolution (Å)3.72
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypeHELICAL
Axial SymmetryC1
Axial Rise5.1
Angular Rotation-100.8
Map-Model Fitting and Refinement
Id1 (4IFP)
Refinement Space
Refinement ProtocolRIGID BODY FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)52.3
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)
Maximum Defocus (nm)
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification81000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONSerialEM
CTF CORRECTIONCTFFIND4.1
MODEL FITTINGPHENIX
RECONSTRUCTIONRELION3.1
MODEL REFINEMENTPHENIX
MODEL REFINEMENTREFMAC
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION118006