7Z9Q
CRYO-EM STRUCTURE OF SARS-COV-2 SPIKE : H11-A10 nanobody complex
ELECTRON MICROSCOPY
Starting Model(s)
Initial Refinement Model(s) | |||
---|---|---|---|
Type | Source | Accession Code | Details |
experimental model | PDB | 6ZHD |
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
r_dihedral_angle_2_deg | 29.835 |
r_lrange_it | 17.501 |
r_lrange_other | 17.501 |
r_dihedral_angle_4_deg | 15.466 |
r_dihedral_angle_3_deg | 13.488 |
r_mcangle_it | 7.486 |
r_mcangle_other | 7.485 |
r_scangle_it | 7.406 |
r_scangle_other | 7.406 |
r_dihedral_angle_1_deg | 6.354 |
Sample |
---|
Complex between Spike and nanobody H11-A10 |
Sample Components |
Spike glycoprotein trimer |
Nanobody H11-A10 |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | SPOTITON |
Cryogen Name | ETHANE |
Sample Vitrification Details | SPT Labtech prototype 300 mesh 1.2/2.0 nanowire grids with a highly reproduceable rectangular bar cross-section were used. The grids were glow-dischar ... |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 305820 |
Reported Resolution (Å) | 3.6 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C1 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (6ZHD, 6ZHD, 6ZHD) | ||||
Refinement Space | RECIPROCAL | ||||
Refinement Protocol | RIGID BODY FIT | ||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K3 BIOQUANTUM (6k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 51.5 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | TFS KRIOS |
Minimum Defocus (nm) | 1500 |
Maximum Defocus (nm) | 3000 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 81000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details | EPU auto-function coma free correction |
EM Software | ||
---|---|---|
Task | Software Package | Version |
IMAGE ACQUISITION | EPU | |
CTF CORRECTION | Gctf | |
MODEL FITTING | UCSF Chimera | |
MODEL FITTING | Coot | |
MODEL REFINEMENT | REFMAC | |
INITIAL EULER ASSIGNMENT | RELION | 3.08 |
FINAL EULER ASSIGNMENT | RELION | 3.08 |
CLASSIFICATION | RELION | 3.08 |
RECONSTRUCTION | RELION | 3.08 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | 3264123 |