3J8A

Structure of the F-actin-tropomyosin complex


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d14.737
f_angle_d1.097
f_chiral_restr0.04
f_plane_restr0.005
f_bond_d0.004
Sample
F-actin-tropomyosin complex
Sample Components
F-actin (alpha)
tropomyosin (alpha)
Specimen Preparation
Sample Aggregation StateFILAMENT
Vitrification InstrumentGATAN CRYOPLUNGE 3
Cryogen NameETHANE
Sample Vitrification DetailsSample was applied to grid, incubated for 10 seconds, and manually blotted for 3 seconds from the backside with filter paper before plunging into liqu ...Sample was applied to grid, incubated for 10 seconds, and manually blotted for 3 seconds from the backside with filter paper before plunging into liquid ethane (GATAN CRYOPLUNGE 3)
3D Reconstruction
Reconstruction MethodHELICAL
Number of Particles
Reported Resolution (Å)3.7
Resolution MethodFSC 0.5 CUT-OFF
Other DetailsThe tropomyosin map filtered to 6.5 Angstrom was merged with the final F-actin map (3.7 Angstrom) to obtain a map of the entire F-actin tropomyosin co ...The tropomyosin map filtered to 6.5 Angstrom was merged with the final F-actin map (3.7 Angstrom) to obtain a map of the entire F-actin tropomyosin complex. Coordinates must be shifted by (0.123 -0.381 0.273) to match coordinates to fibre diffraction standards (filament axis = z axis passing through x=0 and y=0).
Refinement Type
Symmetry TypeHELICAL
Axial SymmetryC1
Axial Rise27.5
Angular Rotation166.4
Map-Model Fitting and Refinement
Id1 (4A7N, 4A7N, 4A7N, 4A7N, 4A7N)2
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FITFLEXIBLE FIT
Refinement TargetR-factorcross-correlation
Overall B Value55.4
Fitting Procedure
DetailsMETHOD--maximum likelihood, flexible fittingMETHOD--flexible fitting
Data Acquisition
Detector TypeFEI FALCON II (4k x 4k)
Electron Dose (electrons/Å**2)14.6
Imaging Experiment1
Date of Experiment2013-10-17
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)800
Maximum Defocus (nm)2600
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification59000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging DetailsCs-corrected microscope
EM Software
TaskSoftware PackageVersion
MODEL FITTINGCoot
MODEL FITTINGDireX
MODEL FITTINGPHENIX
RECONSTRUCTIONSPARX
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
each micrograph