6TZ9
CryoEM reconstruction of membrane-bound ESCRT-III filament composed of CHMP1B only
ELECTRON MICROSCOPY
Sample |
---|
membrane-bound ESCRT-III copolymer filament composed of CHMP1B only |
Specimen Preparation | |
---|---|
Sample Aggregation State | HELICAL ARRAY |
Vitrification Instrument | FEI VITROBOT MARK III |
Cryogen Name | ETHANE |
Sample Vitrification Details | Grids were blotted with Whatman No. 1 filter paper for 4-8 seconds with a 0 mm offset at 19C and 100 percent humidity before plunging into liquid etha ... |
3D Reconstruction | |
---|---|
Reconstruction Method | HELICAL |
Number of Particles | 9661 |
Reported Resolution (Å) | 6.2 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | HELICAL |
Axial Symmetry | C1 |
Axial Rise | 1.86 |
Angular Rotation | 13.86 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 | ||||
Refinement Space | |||||
Refinement Protocol | |||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K2 SUMMIT (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 45 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | |
Maximum Defocus (nm) | |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | |
Nominal Magnification | |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
IMAGE ACQUISITION | SerialEM | |
MODEL REFINEMENT | PHENIX | |
INITIAL EULER ASSIGNMENT | RELION | |
FINAL EULER ASSIGNMENT | RELION | |
RECONSTRUCTION | RELION |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION |