9CMO

Cryo-EM model derived from localized reconstruction of Ad657-hexon-FII complex at 4.14A resolution


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 6B1T 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d14.309
f_angle_d0.668
f_chiral_restr0.044
f_bond_d0.007
f_plane_restr0.005
Sample
Human adenovirus 657 in complex with Coagulation factor FII
Sample Components
Adenovirus657 hexon
Human Coagulation Factor X
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification Instrument
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles4635
Reported Resolution (Å)4.17
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1 (6B1T)
Refinement Space
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 BIOCONTINUUM (6k x 4k)
Electron Dose (electrons/Å**2)81
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)2500
Maximum Defocus (nm)4000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification81000
Calibrated Magnification81000
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION4.0
IMAGE ACQUISITIONEPU
CTF CORRECTIONCTFFIND4
MODEL FITTINGCoot0.9.8
MODEL REFINEMENTPHENIX
INITIAL EULER ASSIGNMENTRELION4
FINAL EULER ASSIGNMENTRELION4
CLASSIFICATIONRELION4
RECONSTRUCTIONRELION4.0
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
NONE