9H1P
Mature HIV-1 matrix from MA-SP1 cleavage mutant
ELECTRON MICROSCOPY
Starting Model(s)
Initial Refinement Model(s) | |||
---|---|---|---|
Type | Source | Accession Code | Details |
experimental model | PDB | 2H3I |
Sample |
---|
HIV-1 vector pNL4-3 |
Sample Components |
HIV-1 mature matrix |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | LEICA EM GP |
Cryogen Name | ETHANE-PROPANE |
Sample Vitrification Details |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 5486693 |
Reported Resolution (Å) | 3.1 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C3 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (2H3I) | ||||
Refinement Space | REAL | ||||
Refinement Protocol | FLEXIBLE FIT | ||||
Refinement Target | cross-correlation | ||||
Overall B Value | 52.49 | ||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | FEI FALCON IV (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 40 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | TFS KRIOS |
Minimum Defocus (nm) | 600 |
Maximum Defocus (nm) | 3600 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 130000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
PARTICLE SELECTION | crYOLO | 1.9.2 |
IMAGE ACQUISITION | EPU | 3 |
CTF CORRECTION | cryoSPARC | 4.3 |
MODEL FITTING | ISOLDE | 1.6 |
INITIAL EULER ASSIGNMENT | cryoSPARC | 4.3 |
FINAL EULER ASSIGNMENT | cryoSPARC | 4.3 |
CLASSIFICATION | cryoSPARC | 4.3 |
RECONSTRUCTION | cryoSPARC | 4.3 |
MODEL REFINEMENT | PHENIX | 1.21 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | A new model was trained in crYOLO using a training dataset annotated in a randomly selected set of 50-100 micrographs. Annotation was performed in the crYOLO boxmanager GUI placing positions all over the visible surface of an HIV virus particle. The picks did not distinguish individual proteins or membranes. |