5O6A
The cryo-EM structure of Tick-borne encephalitis virus mature particle
ELECTRON MICROSCOPY
Starting Model(s)
Initial Refinement Model(s) | |||
---|---|---|---|
Type | Source | Accession Code | Details |
experimental model | PDB | 2SVB |
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
r_dihedral_angle_2_deg | 29.111 |
r_dihedral_angle_3_deg | 9.194 |
r_long_range_B_refined | 8.62 |
r_long_range_B_other | 8.62 |
r_dihedral_angle_4_deg | 7.879 |
r_dihedral_angle_1_deg | 6.542 |
r_mcangle_it | 2.822 |
r_mcangle_other | 2.822 |
r_scangle_other | 1.706 |
r_mcbond_it | 1.491 |
Sample |
---|
Tick-borne encephalitis virus (strain HYPR) |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | FEI VITROBOT MARK IV |
Cryogen Name | ETHANE |
Sample Vitrification Details | Wait time: 10 s Blot time: 2 s Blot force: -2 Drain time: 0 s |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 11882 |
Reported Resolution (Å) | 3.9 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | I |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (2SVB) | ||||
Refinement Space | RECIPROCAL | ||||
Refinement Protocol | OTHER | ||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details | An initial model was generated based on the known crystal structure of the ecto-domain (PDB:1SVB), Dengue virus type 2 and the Zika virus (PDB:5IRE,3J ... |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | FEI FALCON II (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 22 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | 1500 |
Maximum Defocus (nm) | 3000 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 75000 |
Calibrated Magnification | 75000 |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
PARTICLE SELECTION | EMAN | 2.1 |
IMAGE ACQUISITION | EPU | 2 |
CTF CORRECTION | Gctf | 1.06 |
MODEL FITTING | UCSF Chimera | 1.11 |
MODEL FITTING | Coot | 0.8.7 |
MODEL REFINEMENT | PHENIX | 1.11 |
MODEL REFINEMENT | REFMAC | 5.8.0158 |
INITIAL EULER ASSIGNMENT | RELION | 1.4 |
FINAL EULER ASSIGNMENT | RELION | 1.4 |
CLASSIFICATION | RELION | 1.4 |
RECONSTRUCTION | RELION | 1.4 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION |