8QVN
Cryo-EM structure of Cx26 from Gallus Gallus in bicarbonate buffer
ELECTRON MICROSCOPY
Starting Model(s)
Initial Refinement Model(s) | |||
---|---|---|---|
Type | Source | Accession Code | Details |
experimental model | PDB | 7QEQ |
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
f_dihedral_angle_d | 7.716 |
f_angle_d | 0.482 |
f_chiral_restr | 0.0384 |
f_bond_d | 0.0026 |
f_plane_restr | 0.0024 |
Sample |
---|
Connexin 26 (Gallus Gallus) in 90mmHg PCO2, pH7.4 |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | LEICA EM GP |
Cryogen Name | ETHANE-PROPANE |
Sample Vitrification Details | 3 microlitres protein applied to grid, blot time 7 seconds, in 15% CO2/85%N2 atmosphere |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 161947 |
Reported Resolution (Å) | 2.07 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | D6 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (7QEQ) | ||||
Refinement Space | REAL | ||||
Refinement Protocol | |||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K3 (6k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 41 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | 800 |
Maximum Defocus (nm) | 2000 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 105000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
PARTICLE SELECTION | RELION | 3.1 |
CTF CORRECTION | CTFFIND | 4 |
MODEL FITTING | Coot | 0.9.8.4 |
MODEL REFINEMENT | PHENIX | 1.20.1 |
RECONSTRUCTION | RELION | 3.1 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION |